Wiring; Maintenance And Repairs; Routine Maintenance; Periodical Maintenance - Daikin LBS Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10.

Wiring

A wiring diagram, specific for the units of the LBS-LBT series, is enclosed with these use and
maintenance instructions.
11.

Maintenance and repairs

Suitable maintenance is crucial for obtaining longer life, perfect working conditions and
efficiency of the unit as well as for ensuring the safety features provided by the manufacturer.
12

Routine maintenance

Good operation of the unit requires the condenser to be cleaned periodically (frequency of cleaning
depends on the environment where the unit is installed).
Turn
available, use a long-haired brush and work on the outside of the condenser.
In case of water-cooled condensers have the unit cleaned by a plumber with special descaling
agents.
WARNING
Use safety gloves to protect your hands from possible cuts.
WARNING
Disconnect the unit before working on it.
12.1

Periodical maintenance

Periodically check wear condition of electrical contacts and remote switches; if necessary replace
them.

12.2 Service operations to be carried out by qualified technicians or by the manufacturer

Following operations shall be carried out by qualified technicians or by the manufacturer exclusively.
Under no circumstances the user is allowed to:

12.3 Troubleshooting

During operation following troubles may occur:
1. Compressor stops. The unit is equipped with an overtemperature device which stops the
compressor every time the max. allowable temperature of motor windings is exceeded. Possible
causes are:
2. Ice forms on the evaporator preventing air from flowing regularly.
off the unit and clean it by blowing air from the inside outwards. Should no air jet
replace electrical components
work on the electric equipment
repair mechanical parts
work on the refrigerating system
work on the control panel, ON/OFF and emergency switches
work on protection and safety devices.
- insufficient ventilation of the room where the unit is installed;
- anomaly in mains voltage;
- faulty operation of condenser fan.
Device reset is automatic.
Possible causes are:
- the door is opened too frequently;
- faulty operation of evaporator fan;
- faulty solenoid valve (in models with hot gas defrost);
- faulty defrost heater (in models with electric defrost);
- faulty defrost process. In this case some measures can be taken:
increase defrost termination temperature by some degrees, increase number of defrosts.
high