9. Technische specificaties

This device is not calibrated when purchased!
Regulations concerning environment of use:
 Use this meter only for measurements in CATI, CATII, CAT III (<1000V) and CAT
IV (<600V) environments (see §4)
 Use this meter only in a pollution degree 2 environment (see §5)
Ideal working conditions include:
 Temperature: 18 to 28°C (64°F to 82°F)
 relative humidity: max. 75%
 altitude: max. 2000m (6560ft)
9.1.
General
Max. Voltage
Display
Fuse Protection
Temperature coefficient
Power Supply
Ranging Method
Polarity Indication
Overrange Indication
Battery-Low Indication
Operating Temperature
Storage Temperature
Dimensions
Weight
9.2.
DC Voltage
Range
600mV
6V
60V
600V
1000V
Input Impedance: >10M for all ranges
9.3.
AC Voltage
Range
600mV
6V
60V
600V
1000V
Input Impedance: >10M for all ranges
Frequency Range: 40 to 400Hz
Overload protection: 1000Vdc or ac rms.
9.4.
DC Current
Range
600µA
6mA
60mA
600mA
6A
600V CAT IV, 1000V CAT III
3
5/6-
digit LCD, 2 to 3 samples/sec.
µA/mA-range: 630mA/1000V (Ø10.3x38mm)
10A-range: 10A/1000V (Ø10.3x38mm)
0.1x(specified accuracy)/°C (<18°C or >28°C)
9V NEDA 1604 6F22 006P (incl.)
manual/automatic
" - " is displayed
"OL" is displayed automatically
"
" is displayed
0°C to 40°C (32~122°F) (<80%RH, <10°C non
condensing)
-10°C to 60°C (14~140°F) (<70%RH, battery removed)
190x90x40mm
±500g (incl. battery)
Resolution
100µV
1mV
10mV
100mV
1V
Resolution
100µV
1mV
10mV
100mV
1V
Resolution
0.1µA
1µA
10µA
0.1mA
1mA
Accuracy
(0.5% of rdg + 5 digits)
(0.8% of rdg + 5 digits)
(1.0% of rdg +2 digits)
Accuracy
(1.0% of rdg + 5 digits)
(1.5% of rdg +2 digits)
Accuracy
(1.5% of rdg + 3 digits)
(1.5% of rdg +5 digits)