Possible Problem
The hood is not venting
out properly.
The unit turns on by
itself.
Filter is vibrating
RF Remote control does
not work.
Tempest II Use, Care, and Installation Guide
Possible Cause
Using the wrong size of ducting.
The hood might be hanging to high
from the cook top.
The wind from the opened windows
or opened doors in the surrounding
area are affecting the ventilation of
the hood.
Blockage in the duct opening or
ductwork.
A spot light is shining directly onto
the switch controls.
Filter is loose.
Spring clip is broken on the filter.
Battery is dead.
Poor communication with the liner.
RF Remote lost communication with
the liner.
Troubleshooting
Solutions
Change the ducting to the correct size
Adjust the distance between the cook top
and the bottom of the hood within 24" and
36" range.
Close all the windows and doors to eliminate
the outside wind flow.
Remove all the blocking from the duct work
or duct opening.
The switch controls are light sensitive. A
direct light source onto the switch controls
may disrupt switch functions.
Adjust or change the filter.
Change the spring clip.
Replace battery with type A23 12v.
Remote control must be within 15 ft of liner.
Reset liner and remote by switching power
off at the circuit breaker for 5 minutes.
Place remote on counter top near the liner
and switch the circuit breaker back on.