Technical Specifications - Atlantic CHAUFFÉO Notice D'utilisation Et D'installation

Masquer les pouces Voir aussi pour CHAUFFÉO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN

Technical specifications

Voltage (V)
Resistance
Power (W)
Ø
H
Dimensions
A
(mm)
Real heating time**
Qpr
(Maintenance consumption)
V40 (Amount of hot
water at 40°C)
Weight when empty (kg)
Weight when full (kg)
*Real heating time for heating from 15° to 65°C
**Maintenance consumption in kWh for 24 hours for water at 65°C (ambiance 20°C)
48
100 litres
compact
1,200
570
735
600
B
/
C
590
5 h 32 min
***
1.024
175
31
131
150 litres
compact
230 V single-phase
Shielded
1,650
570
1,000
760
500
590
5 h 38 min
1.37
266
41
191
Diagrammatic representation
Hot water outlet
Hot water
View from below
200 litres
compact
2,200
570
1,250
1,050
800
590
5 h 33 min
1.67
359
50
250
Cover
single phase
Cover
three phase
È
Cold water inlet
Cold water