Télécharger Imprimer la page

Miele PW 5105 Mode D'emploi page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Produktgruppen 512, 592
8 von 34
Note
The plinth may only be used with the following Miele models:
PW 5105
Note
Tools required:
Spirit level for plinth levelling
Open spanner 10 mm for M6 nut
Torx screwdriver, T 20
Note
The fitting kit - Plinth UO 5010 Mat. no. 09038900, or fitting kit - Plinth UG 5010, Mat. no. 09038870, contains
the following:
1 plinth UO 5010 with fitting kit - Plinth UO 5010, Mat. no. 09038900
1 plinth UG 5010, 1 x Front panel, 2 x Side panel, 12 x Raised-head screw M4 x 12.4, with fitting kit -
Plinth UG 5010, Mat. no. 09038870
1 floor fastening accessory pack containing the following: 4 x Clamp, 8 x Galvanised washer B6.4,
4 x Bolt M6 x 20, 4 x Nut M6, 4 x Rawl plug S12, 4 x Washer 8.4, 4 x Hexagon head wood screw 8 x 65,
20 x Spacer plate, 8 x Washer 38 mm Ø
1 information sheet with these instructions and commissioning card. These fitting instructions are called
Fitting instructions - Plinth UO 5010 / UG 5010 .
List of illustrations:
Fig. 1: Plinth height
Fig. 2: Floor fastening drilling plan
Fig. 3: Floor fastening hole dimensions
Fig. 4: Floor fastening
Fig. 5: Plinth UO 5010
Fig. 6: Clamp fitting
Fig. 7: Plinth UG 5010
Abbreviation
UM
A-A
B
C
Table 1: Abbreviation legend
Close the gas stopcock if applicable.
Disconnect the machine from the gas (if applicable) and electric mains and ensure utilities cannot be
switched on again in error.
Mark hole positions in accordance with the drawing, Fig. 2.
Note
The gap between the machine and a wall at the side must be at least 10 mm.
06.01.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Explanation
Miele plinth
Section plane
Floor fastening
Detail
Umbau- und Montageanweisung
M.-Nr. 09059270

Publicité

loading

Ce manuel est également adapté pour:

Uo 5010Ug 5010