• The distance between smoke detectors should not be more than 8 metres.
• When fitting on the ceiling, make sure that the smoke detectors are at least
15 cm from the side walls and 50 cm from the corners.
For installation and attachment, see the diagram 
RWM90_MA_DEGBFRNLIT_103x103_AJ.indd 25
Warning
Avoid the following locations to prevent malfunctions of the smoke
detector:
• Places where expected temperature variations are greater than the
ambient operating temperature (+0°C to +45°C).
• Places where draughts can keep smoke away from the detector, such as
near windows, doors or ventilation shafts.
• Places where vapour, increased air humidity or exhaust fumes may
trigger false alarms, e.g. in kitchens, bathrooms or garages.
• Places where dust or dirt could impair the function of the smoke
detector.
• The highest point in rooms with gable ceilings. The distance to the
highest point of the gable should be at least 30 cm.
Warning
• When marking out the drill holes, make sure there are no electrical
wires or cables, pipes or other important components behind them.
• If in doubt, consult an expert before drilling.
• If you are fitting the smoke detector in a vehicle (such as a camper or
caravan), you must contact the manufacturer or your local dealer first
for information on the most suitable location.