Mounting Material; Technical Data - Hornbach 6145053 Manuel D'installation Et De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14

Mounting material

A fully extracted awning has to withstand extreme
loads at its fastenings. Depending on the wall type
at the installation site, the correct fastening must be
selected in order to ensure a secure fixation.
The table below provides a basic recommendation
of fastenings for different wall types, but a specialist
should be consulted in order to figure out, which fas-
tening is the appropriate one. He will also be able to
inform about the wind resistance class the awning can
withstand after the installation.
WALL TYPE
Concrete
Concrete / C20-C25
Solid brick
Clay brick / MZ
Sand-lime brick / KS
Perforated brick
Clay brick / HLZ
Sand-lime brick / KSL
Aerated concrete
Gas concrete / PB2
Cavity wall
For every mounting material, the specifications of the fastening manufacturer must be observed, e.g. drill
sizes, distances to edges, tensioning torques, drying times etc.

Technical data

MODEL
6145053
Max. width
1400 mm
Max. extension
2550 mm
Weight fabric
280 g/m²
Weight complete
6.8 kg
LOCATION
FASTENING
Ceiling
e.g. TOX Anchor bolt S-Fix Pro 1 A4
Ceiling / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Anchor bolt S-Fix Pro 1 A4
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Masonry Set Wallix
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Masonry Set Wallix
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Mosorny Set Wallix
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall / insulated
e.g. TOX Thermo Proof Plus
WARNING
WARNING
To meet the wind resistance class mentioned in
the declaration of conformity, the installed awn-
ing needs to fulfil these requirements:
The awning is installed with the recommended
type and number of brackets.
The awning is installed under consideration of
the given fastening pull-out forces.
The instructions of the fastening manufacturer
have been respected during installation.
The combination of wall type and mounting mate-
rial used at your installation site might result in a
lower wind resistance class for your awning.
ENGLISH
|
103

Publicité

Table des Matières
loading

Table des Matières