Electrical Connection - Harvia SENTIO Concept R Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
Installation instructions, only for experts

4.7. Electrical connection

1. Unscrew the screws 3 and 4 with a screwdriver.
2. Unscrew the screws 1 and 5 with a screwdriver.
3. Remove the cover plate 2.
5
Connection of Concept R 9 kW and 10.5 kW
(CP-RB-090 / CP-RB-105)
1. Guide the connection cable through
the feed-through 6.
2. Connect the connectors of the connection
cable to the U – V – W – N – PE terminals
of the sauna heater and to the applicable
sauna control unit terminals. Observe the
installation instructions for the sauna control
unit when doing so.
3. Reattach the cover panel 2 to the heater.
p. 18/28
1
2
3
4
U
V
W
N
PE
6

Publicité

Table des Matières
loading

Table des Matières