10.5 ACCESS TO THE ELECTRIC PANEL AND REFRIGERATION UNIT

Access to these zones is authorised only for persons with knowledge and practical
experience of the appliance, particularly concerning safety and hygiene.
Electric panel: When cover "A" is removed, the entire vending machine remains
energised. Total isolation from the electric power supply is only obtained when the plug
is removed from the external magnetothermal switch. Consequently, all those operations
that require the vending machine to be without this protection must only be carried out
by qualified personnel who are aware of the risks involved.
To access the electric panel or the refrigeration unit proceed as follows:
Switch off the machine by acting on the main switch and pull out the plug.
Open the door.
Use a Phillips screwdriver to undo the six screws that fasten cover "A".
To remove the refrigeration unit :
Follow the instructions given above.
Rotate the lever "B" as illustrated.
Ensure that the gasket on the top edge of the evaporator box is completely removed from its seat,
remove the refrigeration unit. PAY ATTENTION to the cables.