IFM ioControl CR2050 Manuel D'utilisation page 116

Table des Matières

Publicité

ioControl
Index
S-idx
Designation
0x2000
0x05
Configuration
IN04
0x06
Configuration
IN05
0x07
Configuration
IN06
0x08
Configuration
IN07
0x09
Configuration
OUT00
116
Data type
Default
rw
USINT
10
rw
USINT
10
rw
USINT
10
rw
USINT
10
rw
USINT
2
Details (CR2052)
0 = 0x00
off Input IN04
3 = 0x03
0���10 000 mV
6 = 0x06
ratiometric 0���1000 ‰
7 = 0x07
0���20 000 µA
9 = 0x09
0���32 000 mV
10 = 0x0A
binary plus switched
11 = 0x0B
binary plus switched
with diagnosis
12 = 0x0C
binary minus switched
14 = 0x0E
frequency
0...30 000 Hz
20 = 0x14
period duration as
ratio 0...1 000 ‰
0 = 0x00
off Input IN05
3 = 0x03
0���10 000 mV
6 = 0x06
ratiometric 0���1000 ‰
7 = 0x07
0���20 000 µA
9 = 0x09
0���32 000 mV
10 = 0x0A
binary plus switched
11 = 0x0B
binary plus switched
with diagnosis
12 = 0x0C
binary minus switched
14 = 0x0E
frequency
0...30 000 Hz
20 = 0x14
period duration as
ratio 0...1 000 ‰
0 = 0x00
off Input IN06
10 = 0x0A
binary plus switched
11 = 0x0B
binary plus switched
with diagnosis
18 = 0x12
16...30 000 Ohm
0 = 0x00
off Input IN07
10 = 0x0A
binary plus switched
11 = 0x0B
binary plus switched
with diagnosis
18 = 0x12
16...30 000 Ohm
0 = 0x00
off Output OUT00
2 = 0x02
binary plus switched
4 = 0x04
PWM output
5 = 0x05
current control
15 = 0x0F
binary plus switched
with diagnosis
16 = 0x10
binary plus switched
with diagnosis +
protection

Publicité