Detailed performance data for the TML 250 lifting magnet
Values for load capacity are based on material S235 JR for the maximumcomparable to AISI 1020 Cold Rolled
Steel with the maximum, vertical breakaway force at 0° deviation from the load axis and additionally under a 6°
inclined load in accordance with EN13155, in each case with a 3:1 safety factor. There are not instructions for
round material, as the TML 250 is optimised for flat material and round material or arched objects may not be lifted.
Table 2
Thickness of
material
mm
2
3
4
5
6
8
10
15
>20
Thickness of
material
Inches
0.08
0.12
0.16
0.20
0.25
0.30
0.40
0.50
>1
The maximum dimensions of the loads to be lifted depend to a large extent on the geometry and resistance to
bending of the workpieces, since an air gap forms under the magnetic surface if the workpiece bends, thus
significantly reducing the load-bearing capacity.With each lifting operation, watch for any deformation of the
workpiece that might occur and, if necessary, check for any air gap developing at the edges of the TiN-coated
magnetic surface (e.g. with a sheet of paper; 80g/m
safely lift large or flexible loads.
Immediately stop the lift if there is any excessive deformation or an air gap.
Never exceed the dimensions and/or the load-bearing capacity of the material thickness given in
the table 2.
Load capacity in kg
Clean, flat, ground
surface
Air gap <0.1 mm
50
45
90
80
145
130
180
165
205
185
240
220
250
230
250
230
250
230
Load capacity in lbs
Clean, flat, ground
surface
Air gap <0.004 inches
110
100
200
185
315
290
400
365
455
415
530
485
550
515
550
515
550
515
Rusty, slightly
scratched surface
Air gap = 0.25 mm
40
35
80
70
110
100
135
125
155
140
165
150
180
165
180
165
180
165
Rusty, slightly
scratched surface
Air gap = 0.01 inches
85
75
175
160
240
220
295
270
340
310
360
330
395
360
395
360
395
360
2
). Spreader bars with additional magnets may be required to
Irregular, rusty or
rough surface
Air gap = 0.5 mm
32
30
65
60
90
80
100
90
105
95
110
100
110
100
115
105
115
105
Irregular, rusty or
rough surface
Air gap = 0.02 inches
70
65
140
125
200
180
220
200
231
210
240
220
240
220
250
230
250
230
17