Maintenance and inspection of the lifting magnet
The user is obliged to maintain and service the lifting magnet in compliance with the specifications in the operating
manual and according to the country-specific standards and regulations (e.g. ASME B30.20B, DGUV-Information
209-013; AMVO).
The maintenance intervals are classified according to the frequency with which the maintenance should be carried
out:
Before every use...
check the lifting magnet for visible signs of damage
clean the surface of the workpiece and the underside of the magnet
free the underside of the magnet of rust, chips or unevenness
check the blocking function of the safety tab on the lever
Weekly...
check the lifting magnet and load hook for deformation, cracks or other defects
check that the operating lever and safety tab are working properly
check the load hook for damage or wear and have it replaced if necessary
check the underside of the magnet for scratches, pressure points or cracks and have the magnet repaired
by the manufacturer if necessary
Monthly...
check the markings and labelling on the lifting magnet for legibility and damage and replace if necessary
Annually...
have the load-bearing capacity of the lifting magnet checked by the supplier or an authorized workshop
An annual inspection is recommended for the safe use of this lifting magnet. We will be glad to perform this
inspection for you in-house. Please send us an email to:
You will then promptly receive an offer and have the assurance that the lifting magnet will be inspected in a
process-reliable manner where it was actually produced.
Unauthorized repairs or modification to the lifting magnet are not permitted.
Please contact the manufacturer if you have any questions or queries.