Technical data

Location
Materials
Sealing
Environment
Operating temperature
Operating altitude
Hygrometry
Pollution degree
Weight

Mechanical data

Nominal torque
Maximum torque
Operating time (90°)
Angular range
Duty cycle
Drive ISO5211
Manual control

Electrical data

Voltages
1)
Rated current
Overvoltage category
2)
Power
Torque limiter
Number of feedback switches
Limit switches maximum voltage
Limit switches maximum current
Anticondensation heaters
1)
The actuator tolerates voltage fluctuation of the electrical grid up to ± 10 % of its nominal system operating voltage
The actuator tolerates temporary overvoltage of the electrical grid
2)
20
VTX600
ATEX : II 2 G D Ex d IIB T5 Gb Ex tb IIIC T90°C Db LCIE 15 ATEX 3012 X
Both inside and outside (wet environments possible)
maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% rela-
Applicable POLLUTION DEGREE of the intended environment is 2
450Nm
600Nm
42s
Star 36 (depth 41mm) • F10/F12 (depth F10 : 25mm / F12 : 30mm)
Secured hand wheel without clutching system
230 V AC (50/60 Hz) • 3-phase 400 V (50 Hz)
400 V: 0,45 A (cos  = 0,8) • 230 V: 1,3 A (cos  = 0,8)
4 to 250V AC/DC (Overvoltage category II)
Housing: Aluminium + EPOXY paint
Drive : Steel + Zn treatment
Shaft and screws : Stainless steel
IP68
-20°C to +63°C
Up to 2000m
tive humidity at 40°C
(in most cases).
25kg
90° (180°-270° on request)
50%
250W
Mechanical
2 (4 on request)
1mA to 5A max
10W
ENGLISH
UK
VTX1000
600Nm
1000Nm
65s
DSBA3003 • Rév. 07/07/2020