Télécharger Imprimer la page

BFT ARES ULTRA BT A 1000 Instructions D'utilisation Et D'installation page 24

Actionneur pour portails coulissants a cremaillere
Masquer les pouces Voir aussi pour ARES ULTRA BT A 1000:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
x2
0---
ALT
follow the user guide
add. start
Add. 2ch
erase 64
language
autoset
stat
vers
OK
No total
- +
manoeuvres(in hundreds)
n. cycles
OK
- +
n. remotes
OK
- +
List of last 30 errors
OK
err
0---
password
24 -
ARES ULTRA BT A 1000 - ARES ULTRA BT A 1500
ACCESS MENUS Fig. 2
10--
150-
hidden butt
release
hidden butt
release
Diagnostics
code
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
BAR
BAR 2
baro
barc
SWC
SWO
SET
ER01
ER02
Control unit
ER03
software version
bft . . .
ER04
+/-
ER05
er06
0000
ER07
+/-
ER08
No radio control
devices memorised
ER1x*
00
ER3x*
+/-
ER4x*
01.33
ER5x*
ER70, ER71
02.01
ER74, ER75
........
ER72
30.15
+/-
ER73
ERf0
erf1
ERf3
* X = 0,1,...,9,A,B,C,D,E,F
10--
1520
ok
See PARAMETERS MENU
See LOGIC MENU
desired button
desired button
See RADIO MENU
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
PHOT photocell input activated
PHOT OP opening photocell input activated
PHOT CL closing photocell input activated
BAR safety edge input activated
BAR safety edge input activated on slave motor
(opposite leaves connection)
Activation of BAR safety edge input with ACTIVE reversal
ONLY WHILE OPENING, or, if configured as verified safety
edge active only while opening, Activation of the asso-
ciated FAULT input
Activation of BAR safety edge input with ACTIVE rever-
sal ONLY WHILE CLOSING, or, if configured as verified
safety edge active only while closing, Activation of the
associated FAULT input
SWC motor closing limit switch input activated
SWO motor opening limit switch input activated
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
Safety edge test on slave motor failed (opposite leaves
connection)
8k2 safety edge test failed
Opening safety edge test failed
Closing safety edge test failed
Board hardware test error
Reverse due to obstacle - Amperostop
Thermal cutout
Communication error with remote devices
Internal system supervision control error.
Consistency error of the control unit's parameters (Logics
and Parameters)
D-track parameter error
Limit switch error
Limit switch error always active after operation start
Error in setting the SAFE inputs
150-
1520
Request with Protection Level logic set to 1, 2, 3, 4
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory devices
and/or expansion boards
Try switching the board off and back on again. If the problem
persists, contact the technical assistance department.
Pressing OK the detected settings are confirmed. The board will
keep on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as
a default.
An autoset is required
check limit switch connections
Check limit switch and motor connections
Check the setting of the SAFE inputs is correct
prg
*** Password entry.

Publicité

loading

Ce manuel est également adapté pour:

Ares ultra bt a 1500Ultra ares ultra bt a 1000Ultra ares ultra bt a 1500