8. TROUBLE SHOOTING

(ATTENTION: before start-up tests and/or repairs check that the electronic circuit board parameters
correspond with the check list held by the after-sales service engineer).
PROBLEM
Control panel
not turns on
Stove not igniting.
Alarm on display
"AlAr no FirE"
Pellets not reaching
combustion chamber
Fire extinguishes
and stove stops
Stove working
Display shows
"Stop FirE"
MARTINA-SOLARIS-ALESSIA-VANESSA
CAUSE
Stove without power supply
Circuit board protection fuse burnt
out
Faulty control panel
Faulty flat cable
Faulty electronic circuit board
Hopper empty
Burn pot has not been cleaned
Probe has not reached ignition
threshold
Faulty ignition spark plug
External temperature too low
Damp pellets
Heat probe blocked
Faulty electronic circuit board
Hopper empty
Auger clogged by foreign object
(e.g. nails)
Auger gear motor broken down
Check for active alarm on display
(Alar dep, Alar sic.)
Hopper empty
Auger clogged by foreign object
(e.g. nails)
Low quality pellets
Value set on circuit board for stage 1
too low
Check for active alarm on the display
(Alar dep, Alar sic.)
Burn pot dirty
Check that plug is plugged into mains.
Replace board protection fuse.
Call an expert.
Replace control panel display.
Call an expert.
Replace flat cable.
Call an expert.
Replace electronic circuit board.
Call an expert.
Fill hopper
Clean burn pot:
Empty burn pot and light again; if problem
persists call an expert
Replace ignition heating element.
Call an expert.
Start stove again.
Pellets must be stored in a dry place, check.
Replace fumes probe.
Call an expert.
Replace electronic circuit board.
Call an expert.
Fill hopper.
Unplug, remove hand protection in the hopper,
empty, clean auger and re-start.
Replace 5RPM gear motor.
Call an expert.
Have an expert inspect stove to find the causes.
Fill hopper.
Unplug, remove hand protection in the hopper,
empty, clean auger and re-start.
Try using other types of pellets.
Have an expert regulate pellet delivery.
Have an expert inspect stove to find the causes.
The
stove
operating
extraction on maximum, no problem.
SOLUTION
see paragraph 7.5, page 81.
on
minimum,
fumes
Pag. 85