Use the front pushbutton to activate the IrDA interface,
see figure on Pg 42.
DIP switches
All (1 ... 8)
ON
OFF
As desired
You can install the "Paraly SW 111" software for infrared communica-
tion on a PC or PDA. It allows configuring all transmitter parameters
(see table on Pg 45). The software comes with detailed instructions
which are also available for download at "www.knick.de".
Additional functions of the temperature transmitter when using
"Paraly SW 111" software:
- Teach in
- Plain-text error signaling
- Input and measurement of power resistance with 2-wire R/RTD
- PT1 filter
- Characteristics
- High resolution for start and end values
- Simulation
- Indication of measured value and output value
- TAG allocation (identifier)
- Password protection

Communication via IrDA Interface

Function via IrDA interface
Rotary
switches
Start
End
0 0
0
0
PROG, read / write;
IrDA configuration active
0 0
0
0
DATA, read only;
IrDA configuration active
Read only;
switch configuration active