BFT Vega Instructions D'installation page 36

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
of the procedure, otherwise
5. Apply a shock absorber profile
6. Check the impact forces again: if they fall within the limits (**) skip to point 10
of the procedure, otherwise
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
safety edge) (**)
8. Check the impact forces again: if they fall within the limits (**) skip to point 10
of the procedure, otherwise
9. Allow the drive to move only in "Deadman" mode
10. Make sure all devices designed to detect obstacles within the system's operating
range are working properly
(*) Before running the autoset function, make sure you have performed all the
assembly and make-safe operations correctly, as set out in the installation
warnings in the drive's manual.
(**) Based on the risk analysis, you may find it necessary to apply sensitive
protective devices anyway
9.8) LIMIT SWITCH ADJUSTMENT MENU (reg. f c)
The menu is active only with ULTRA motors. It allows adjusting PHEBE ULTRA
motor limit switches.
The limit switch adjustment menu allows modifying factory-set closing and
opening points.
Adjustment of the closing point is automatic at every AUTOSET; however, it can
be modified acting on the limit switch adjustment menu:
1) from the REG FC (Limit Switch Adjustment) menu, confirm with OK
2) the display reads Close, confirm with OK
3) the display reads position SWC, use the UP and DOWN keys to move the door
to the closing position. Confirm with OK, the display reads PRG and the card
stores the position.
Adjusting the opening point is carried out setting the desired opening in degre-
es; to modify the opening, act on the limit switch adjustment menu.
1) from the REG FC (Limit Switch Adjustment) menu, confirm with OK
2) the display reads Close, use the DOWN key and move to the Opening M1
menu, confirm with OK
3) set the desired opening with the UP and DOWN keys, confirm with OK: the
display shows PRG.
If the configuration with 2 active motors is used, there are 2 separate opening
adjustment menus for motor 1 and motor 2; the adjustment of motor 1 acts
automatically on motor 2 adjustment; if, because of the conditions of the instal-
Terminal
JP2
10
JP11
11
14
15
16
20
AUX 0 - 24V POWERED CONTACT
21
26
AUX 3 - FREE CONTACT (N.O.)
27
28
29
36
37
41
JP24
42
43
50
51
52
60
61
70
71
72
73
Y
#
36
- VEGA - VEGA ULTRA
INSTALLATION MANUAL
Definition
Board power supply:
TRANSF SEC
24V~ Transformer secondary winding
MOT +
M1 motor connection (MOT+ brown / MOT- blue)
MOT -
MOT +
M2 motor connection (if applicable MOT+ brown / MOT- blue)
MOT -
SWO 2
Motor 2 opening limit switch SWO2 (N.C.). (COM 70)
AUX 0 configurable output - Default setting FLASHING LIGHT.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR
LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT
(N.O.)
AND MAINTENANCE / ANTITAMPERING / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to "AUX output configuration" table.
AUX 3 configurable output - Default setting MONOSTABLE RADIO CHANNEL
Output MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/
STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/MAINTENANCE/ FLASHING
LIGHT AND MAINTENANCE / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL
Refer to "AUX output configuration" table
LOCK 12/24V
5-6 Solenoid lock 24V or intermittent flashing light max. 24V 3W (LG2 logic)
0V
BFT courtesy light connection.
+V
COM
Limit switch common
SWC 1
Motor 1 closing limit switch SWC1 (N.C.).
SWO 1
Motor 1 opening limit switch SWO1 (N.C.).
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe+
Output active only during operating cycle.
Common
IC 1 inputs common
Configurable command input 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Common
Inputs common STOP, SAFE 1, SAFE 2 and SWO2 (if applicable)
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default PHOT.
SAFE 1
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the "Safety input configuration" table.
FAULT 1
Test input for safety devices connected to SAFE 1.
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close
to the antenna can interfere with radio reception. If the transmitter's range is limited, move the antenna to a more
SHIELD
suitable position.
lation, opening is incorrect, it is possible to offset the opening value of motor 2
in the opening adjustment menu of motor 2.
9.9) STATISTICS MENU (STAT)
Used to view the version of the board, the total number of operations (in
hundreds), the number of transmitters memorized and the last 30 errors (the
first 2 digits indicate the position, the last 2 give the error code). Error 01 is the
most recent.
9.10) PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access
the programming menus. After 10 consecutive failed attempts to log in, you will
need to wait 3 minutes before trying again. During this time, whenever an attempt
is made to log in, the display will read "BLOC". The default password is 1234.
10) CONNECTION WITH EXPANSION BOARDS
Please refer to specific manual.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
11) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using
an appropriate antenna tuned to 433MHxz.
12) RESTORING FACTORY SETTINGS (Fig.G)
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.G ref.1)
- Open the Stop input and press the - and OK keys together (Fig.G ref.2)
- Switch on the board's power (Fig.G ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.G ref.4)
- Wait for the procedure to finish (Fig.G ref.5)
- Procedure finished (Fig.G ref.6)
Description

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vega ultra

Table des Matières