TECHNICAL DATA

MODEL
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at max. delivery
(2)
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
MOTOR CAPACITOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(2) Pressure at test point 5)(A)p.8, with zero pressure in the combustion chambre.
(2) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.
COUNTRY
IT-AT-GR-DK-FI-SE
ES-GB-IE-PT
NL
FR
DE
BE
LU

ACCESSORIES

(optional):
POTENTIOMETER KIT Code 3010109
SIGNAL CONVERTER KIT Code 3010390
KIT FOR LPG OPERATION: The kit allows the RX 350-500S/P burners to operate on LPG.
BURNER
RX 350S/P
OUTPUT kW
Code
OUTPUT POWER REGULATOR KIT: Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates
between the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two compo-
nents should be ordered: • Power regulator to install to the burner; • probe to install to the boiler.
PARAMETER TO BE CHECKED
Temperature
Pressure
KIT INTERFACE ADAPTER RMG TO PC Code 3002719
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter): see page 16.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
MAX.
MIN.
kWh/Sm
Mcal/Sm
V1 - V2
CATEGORY
II
2H3B/P
II
2H3P
II
2L3B/P
II
2Er3P
II
2ELL3B/P
I
I
2E(R)B,
3P
II
2E3B/P
RX 500S/P
55 ÷ 390
84 ÷ 510
3010391
3010392
Range
- 100...+ 500°C
0...2.5 bar
0...16 bar
RX 350S/P
851 T2
kW
390
335
Mcal/h
kW
55
Mcal/h
47
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
3
9.45
3
8.2
3
0.68
kg/Sm
3
4.13
Sm
/h
mbar
11.5
Boilers: water, steam, diathermic oil
°C
0 - 40
°C max
60
V
230 ~ +/- 10%
Hz
50 - single-phase
rpm
2800
W
300
V
220 - 240
A
2,5
µF / V
12.5/450
230 V - 2 x 5 kV
I1 - I2
1.45 A - 50 Hz - 30 mA
W max
600
IP 44
90/396 - 89/336 - 2004/108 - 73/23 - 2006/95 - 92/42
dBA
68
CE
PROBE
Type
PT 100
Output probe
4...20 mA
6
RX 500S/P
852 T2
510
439
130
112
G25
G20
8.13
9.45
7.0
8.2
0.75
0.68
48
54
16.9
14.7
230 - 400 with neutral ~ +/- 10%
50 - three-phase
2800
650
220/240 - 380/415
3 - 1.7
970
72
POWER REGULATOR
Code
Type
3010110
RWF40
3010213
3010214
GB
G25
8.13
7.0
0.75
62.7
19
Code
3010212