Télécharger Imprimer la page

S+S Regeltechnik THERMASGARD TF 43 Notice D'instruction

Masquer les pouces Voir aussi pour THERMASGARD TF 43:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6000-3040-0000-1XX 30400-2021 V105 02 ⁄ 2021
THERMASGARD
® 
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturfühler,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature sensor
with passive output
F
Notice d'instruction
Sonde de température à immerger ⁄ à visser ⁄ en gaine,
avec sortie passive
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный датчик температуры,
с пассивным выходом
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
TF 43
TF 65
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
TF 43
(IP 54)
TF 65
(IP 67)
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Publicité

loading

Sommaire des Matières pour S+S Regeltechnik THERMASGARD TF 43

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄...
  • Page 2 D G F r Grundgerät mit Zubehör Basic device with accessories Une unité de base avec accessoires Базовый прибор с принадлежности TF 43 ⁄ TF 65 MF - 15 - K Maßzeichnung Maßzeichnung Dimensional drawing Dimensional drawing Plan coté Plan coté M16x1.5 M16x1.5 Габаритный...
  • Page 3 ® THERMASGARD TF 43 ⁄ TF 65 Rev. 2021 - V17 Patentiertes Qualitätsprodukt (Tauchfühler Patent-Nr. DE 10 2012 017 500.0) 1x Zweileiterschaltung THERMASGARD ® TF 43 ist ein Widerstandsthermometer mit passivem Ausgang, Standard Gehäuse aus schlagzähem Kunststoff mit Schnappdeckel, und geradem Schutzrohr. ®...
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Anschluss Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden technischen Parameter der Thermometer mit den realen Einsatzbe- der Geräte darf nur an Sicherheitskleinspannung er folgen. Folgeschäden, dingungen zu erfolgen, insbesondere: welche durch Fehler an diesem Gerät entstehen, sind von der Gewährlei- –...
  • Page 6 ® THERMASGARD TF 43 ⁄ TF 65 Rev. 2021 - V17 Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) 1x two-wire connection THERMASGARD ® TF 43 is a resistance thermometer with a passive output, Standard housing made from impact-resistant plastic with snap-on lid, and straight protective tube. ®...
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical parameters comply with the actual conditions at the place of utilization, in only be connected to safety extra-low voltage. Consequential damages particular in respect of: caused by a fault in this device are excluded from warranty or liability.
  • Page 9 ® THERMASGARD TF 43 ⁄ TF 65 Rev. 2021 - V17 Produit de qualité breveté (Sonde à immerger, n° de brevet DE 10 2012 017 500.0) 1 x 2 fils ® THERMASGARD TF 43 est un thermomètre à résistance avec sortie passive, Standard boîtier en matière plastique résistante aux chocs, avec couvercle emboîté, et tube de protection droit.
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé...
  • Page 11 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux conditions d’utilisation Veillez à ne brancher l’appareil que sur un réseau de très basse tension de réelles, notamment : sécurité.
  • Page 12 ® THERMASGARD TF 43 ⁄ TF 65 Rev. 2021 - V17 Запатентованный высококачественный прибор (погружной датчик: патент № DE 10 2012 017 500.0) 1x Двухпроводное подключение ® THERMASGARD TF 43 — это термометр сопротивления с пассивным выходом, стандартное корпусом из ударопрочного пластика с защелкивающейся крышкой, и прямой защитной трубкой. THERMASGARD ®...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Монтаж следует осуществлять с учетом соответствия прилагаемых технических параметров термометра реальным условиям эксплуатации, должно осуществляться исключительно к безопасно малому напряжению. в особенности: Повреждения приборов вследствие несоблюдения упомянутых требований –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 81-210 (KP10) °...

Ce manuel est également adapté pour:

Thermasgard tf 65