S+S Regeltechnik THERMASGARD TF 54 Notice D'instruction

Masquer les pouces Voir aussi pour THERMASGARD TF 54:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6003-0500-2012-000 30500-2016 V100 11 ⁄ 2015
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturfühler,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature sensor
with passive output
F
Notice d'instruction
Sonde de température à immerger ⁄ à visser ⁄ en gaine,
avec sortie passive
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный датчик температуры,
с пассивным выходом
TF 54
standard
(IP 54)
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
TF 54
TF 54
optional
(IP 65)
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.

Publicité

Table des Matières
loading

Sommaire des Matières pour S+S Regeltechnik THERMASGARD TF 54

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r TF 54 THERMASGARD ®  2-Leiteranschluss (Standard) TF 54 Maßzeichnung 2-wire connection (standard) Dimensional drawing 1x 2 fils (Standard) Plan coté Двухпроводное соединение Габаритный чертеж (стандартное исполнение) ~ 80 M20 x1,5 ø70 4-Leiteranschluss (optional) 4-wire connection (optional) 1x 4 fils (en option) Четырехпроводное...
  • Page 3: Technische Daten

    THERMASGARD ® TF 54 Rev. 2016 - V11 DE Widerstandsthermometer ⁄ Temperaturfühler THERMASGARD ® TF 54 mit geradem Schutzrohr, 1x Zweileiterschaltung Anschlusskopf aus Aluminium. Es dient zur Erfassung von Temperaturen in flüssigen oder Standard gas förmigen Medien, in Rohr leitungen, Behältern oder Speichern. TECHNISCHE DATEN Messbereich: –35...+180 °C...
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5: Montage Und Installation

    Montage und Installation Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorlie- genden technischen Parameter der Thermometer mit den realen Anschluss der Geräte darf nur an Sicherheitskleinspannung er- Einsatzbedingungen zu erfolgen, insbesondere: folgen.
  • Page 6: Technical Data

    THERMASGARD ® TF 54 Rev. 2016 - V11 GB Resistance thermometer ⁄ temperature sensor THERMASGARD ® TF 54 with straight protective 1x two-wire connection tube and connection head made of aluminium. It is used for measuring temperatures in liquid or Standard gaseous media, in piping systems, in vessels or storage tanks.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Mounting and Installation Devices are to be connected under dead-voltage condition. Devices Before mounting, make sure that the existing thermometer‘s techni- cal parameters comply with the actual conditions at the place of must only be connected to safety extra-low voltage. Consequential utilization, in particular in respect of: damages caused by a fault in this device are excluded from war- ranty or liability.
  • Page 9: Caractéristiques Techniques

    THERMASGARD ® TF 54 Rev. 2016 - V11 FR Thermomètre à résistance ⁄ sonde de température THERMASGARD ® TF 54 avec tube de 1 x 2 fils protection droit et tête de raccordement en aluminium. Il sert à mesurer les températures en milieu Standard liquide ou gazeux, dans les conduites et les réservoirs.
  • Page 10: Généralités

    Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé...
  • Page 11: Montage Et Installation

    Montage et installation Les raccordements électriques doivent être exécutés HORS Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux TENSION. Veillez à ne brancher l’appareil que sur un réseau de très basse tension de sécurité. Nous déclinons toute responsabi- conditions d’utilisation réelles, notamment : lité...
  • Page 12: Технические Данные

    THERMASGARD ® TF 54 Rev. 2016 - V11 RU Термометр сопротивления ⁄ датчик температуры THERMASGARD ® TF 54 с прямой защитной 1 Двухпроводное подключение трубкой, присоединительной головкой из алюминия. Предназначен для определения температуры стандартное в жидких или газообразных средах, в трубопроводах, резервуарах или коллекторах. ТЕ...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Под- Монтаж следует осуществлять с учетом соответствия прилагаемых тех- ключение должно осуществляться исключительно к безопасно нических параметров термометра реальным условиям эксплуатации, малому напряжению. Повреждения приборов вследствие несо- в особенности: блюдения упомянутых требований не подлежат устранению по –...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 91-210 (KP10) °...

Table des Matières