Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff BTL5-T1 Série Notice D'utilisation

Masquer les pouces Voir aussi pour BTL5-T1 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL5-T1 _ _ -M _ _ _ _ -P-S103
Magnetostrictive Linear Position Sensor – Profile Style
6

Technical data

6.1

Accuracy

The specifications are typical values for BTL5-T... at
24 V DC, and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2
BTL6-A-3801-2
, BTL5-F-2814-1S, BTL5-T-2814-1S,
1)
BTL5-M-2814-1S or BTL5-N-2814-1S magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
Non-linearity
Hysteresis
Reproducibility
Temperature coefficient
2)
Velocity resolution
Velocity detectable max.
6.2

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Shock rating
Continuous shock
per EN 60068-2-27
4), 5)
Vibration
per EN 60068-2-6
4), 5)
Degree of protection per
IEC 60529
when threaded together
14
english
BTL6-A-3800-2
,
1)
1)
5 µm
±30 µm
< 1 LSB
< 2 LSB
< (6 µm + 5 ppm
× nominal length)/K
0.1 mm/s
10 m/s
3)
–40 °C...+85 °C
–40 °C...+100 °C
< 90%, non-
condensing
100 g/6 ms
100 g/2 ms
12 g, 10...2000 Hz
IP67
6.3

Supply voltage (external)

Stabilized voltage
6)
Residual ripple
Current draw (at 24 V DC)
7)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
6.4

Control signals

RxD/TxD-N, RxD/TxD-P, Data GND per EN 50170
6.5

Magnet

Max. number of magnets
6.6

Dimensions, weights

Nominal length
Weight (depends on length)
Housing material
6.7

Connection to the evaluation unit

Maximum length of the entire field bus cable is 1200 m.
Cable twisted in pairs, shielded see Fig. 4-10.
In the position range 0 to 20 mm, the specified linearity limit can be
1)
exceeded by ±100 µm.
Nominal length 500 mm, magnet in the middle of the measuring range
2)
3)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
4)
Individual specifications as per Balluff factory standard
Resonant frequencies excluded
5)
For
: The BTL must be externally connected via a limited-energy
6)
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
7)
Depending on the load on VP (repeater, bus termination)
Number dependent on nominal length (see section 3.3)
8)
20...28 V DC
≤ 0.5 V
PP
≤ 130 mA
≤ 3 A
yes
Transzorb
protection diodes
500 V DC
4
8)
50...4000 mm
Approx. 1.4 kg/m
Aluminum

Publicité