Operating Modes; Exhaust-Air Mode; Circulating-Air Mode - Gaggenau AI 400120 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35

Operating modes

The extractor hood can be used in exhaust air
and circulating air mode. The standard setting
is exhaust air mode.

Exhaust-air mode

Installation accessories for exhaust air mode
Stainless steel-design ventilation duct:
AD 010-016 for ceiling heights of 2.23-2.41 m
AD 010-026 for ceiling heights of 2.41-2.73 m
AD 010-036 for ceiling heights of 2.73-2.99 m.
The air which is drawn in is cleaned by the grease
filters and conveyed to the exterior by a pipe
system.
Appliance dimensions Exhaust air
min. 580 mm
max 1.414 mm
24

Circulating-air mode

Installation accessories for circulating air mode
Stainless steel-design ventilation duct:
AD 010-126 for ceiling heights of 2.41-2.73 m
AD 010-136 for ceiling heights of 2.73-2.99 m.
The air which is drawn in is cleaned by the grease
filters and an activated carbon filter and conveyed
back into the kitchen.
An activated carbon filter must be installed to bind
odours in circulating-air mode (see "Removing and
installing the grease filters").
The complete installation set as well as the
replacement filters are available from specialist
outlets, customer service or the Online Shop. The
accessory number can be found at the end of the
operating instructions.
The socket must be attached at least 170 mm below
the ceiling.
Appliance dimensions Circulating air
min.
155 mm
min. 580 mm
max 1.520 mm
min.
35 mm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ai 400150Ai 402120Ai 402150

Table des Matières