Cleaning and maintenance

7.15

Replacing the plug fuse (DC)

➤ Unscrew the contact pin housing (fig. 7 3, page 5) from the plug (fig. 7 1,
page 5).
➤ Replace the defective fuse (fig. 7 2, page 5) with a new fuse that has the same
rating (3AG, 15 A).
➤ Re-assemble the plug in reverse order.
7.16

Replacing the light PCB

➤ Disconnect the power supply to the device.
➤ Pry out the transparent cover with a screwdriver (fig. 8 A, page 5).
➤ Unscrew the PCB mounting screws (fig. 8 B, page 5).
➤ Pull out the plug from the PCB (fig. 8 C, page 5).
➤ Replace the defective light PCB with a new one.
➤ Fit new PCB using reverse of removal instructions.
➤ Press the transparent cover back into the housing.
➤ Reconnect the power supply to the device.
8
Cleaning and maintenance
!
WARNING!
Always disconnect the device from the power supply before you clean
and service it.
A
NOTICE! Risk of damage
• Never clean the cooler under running water or in dish water.
• Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooler.
➤ Occasionally clean the device interior and exterior with a damp cloth.
➤ Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.