Télécharger Imprimer la page

Siemens RVL482 Mode D'emploi page 58

Masquer les pouces Voir aussi pour RVL482:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
Block "Switching program 3"
151 Weekday (for
switching program
3)
152 Start of first ON
en
period
153 End of first ON
period
154 Start of second ON
period
155 End of second ON
period
156 Start of third ON
period
157 End of third ON
period
Block "Service functions and general settings"
161 Outside tempera-
ture simulation
162 Relay test
Building Technologies
1-7
(1...7)
.........................
06:00
(00:00...24:00)
.........................
22:00
(00:00...24:00)
.........................
--:--
(00:00...24:00)
.........................
--:--
(00:00...24:00)
.........................
--:--
(00:00...24:00)
.........................
--:--
(00:00...24:00)
.........................
--.- °C
(--.- / −50...+50)
...................
0
(0...13)
74 319 0619 0 a
1 = Monday
2 = Tuesday, etc.
1-7 = entire week
Switching program 3
--:-- = period inactive
Simulation automatically termi-
°C
nated after 30 minutes
--.- = no simulation
0 = normal operation
1 = all contacts open
2 = burner stage 1 ON K4
3 = burner stages 1 ON K4
and 2 ON / burner modula-
tion actuator OPEN K5
4 = circulating pump / bypass
pump ON M1
5 = charging pump ON M3
6 = heating circuit mixing valve
OPEN Y1
7 = heating circuit mixing valve
CLOSED Y2
17.04.2008
58/288

Publicité

loading