The discharge pressure is too
high
The discharge line is incorrectly
Motor
sized
overheats
The power supply does not cor
respond the electronic specificat
ions
Wrong electrical connections
Lack of lubricant in the mechan
Work
ism/gearbox
with noise
Excessive wear of the mechani
sm/gearbox
Pipe diameter too small
The pipeline
Pulsation damper out of operation
vibrates
or too small

6. Handling and storage

6.1 Handling

Here below is instructions for handling
- Do not sling, pull, push the pump head nozzles or flanges
- Do not sling, pull, push the adjustment knob
6.2 Storage
Precautions
During shipment and storage, the protection against rain, sand, dust, dirty and direct sunlight are
required.
Should the pump be stored for a long time, please store it in a dry and ventilated place.
Important Instruction for MSA/MSV Series
1) Please make sure that this instruction is attached to the pump
2) Make sure that the voltage and frequency is matched. Power supply: 380V/50Hz (or
220V/50Hz, refer to label for details), the motor temperature should be lower than 80
normal operation; It is strictly forbidden to operate without liquid for long time (not exceeding 3
minutes)
3) The pump is unable to work at the pressure exceeding its rated pressure (max working
pressure), and its rated pressure value is marked on the label, expressed by bar
(1bar=1kg/cc=10mlift). If the pump works overpressure, it might be damaged.
4) When the chemical to be dosed reacts to water, for example concentrated sulfuric acid, the
chamber must be cleaned and dried (some water drop might be left while testing at our factory)
5) When the adjustment knob is positioned below 100% graduation, the voice from internal
mechanism is relatively big, this is normal, in addition, we suggest you not to position below 30%
graduation.
6) Please make sure that the discharge/ suction line is installed correctly, and the suction line
(suction valve) is installed downward vertically; the discharge line (discharge valve) is installed
upward vertically; the discharge valve does not replace the suction valve each other. Loss of any
SPR0136037
Check the setting of pressure relief valve
Check the length and diameter of discharge
line
Make
sure
corresponds to motor
Check and rectify connections
Refill with the correct lubricant
Overhaul mechanism/gearbox
Enlarge pipe diameter
Repair or recalculate damper volume
Rev. 1.5