Ordering Spare Parts - Euromate SFE-25 Manuel Opérateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10.1
SFE malfunctioning
Problem
Extraction capacity insufficient.
Dust or smoke from the outlet grid
and/or indicator blinks or is not lit.
Machine makes a crackling sound
(= short-circuit).
10.2
HFE malfunctioning
Problem
Motor does not start.
Motor stops automatically.
Extraction capacity insufficient.
Dust or smoke from the outlet grid
and/or indicator blinks or is not lit.
Machine makes a crackling
sound (= short-circuit).
11

ORDERING SPARE PARTS

For spare parts available for the machine consult the supplied exploded
view.
Address your order to your supplier and always
state the data below:
- product name, supply voltage and serial number
(see the identification plate)
14
Possible cause
Filters clogged or saturated (*).
False air is being sucked (*).
Ioniser and/or collector are saturated or mounted
incorrectly (*) causing short-circuiting.
No power on filtercell(s).
Poor contacts in the ioniser and/or collector.
High-voltage transformer defective.
High-voltage PC board defective.
Short-circuit in the ioniser and/or collector (caused by
bent lamellas).
Ioniser and/or collector incorrectly mounted.
Ioniser and/or collector heavily polluted.
Ioniser and/or collector not totally dry.
Bent collector lamellas.
Bent or broken ionisation wires.
Metal particles in ioniser and/or collector.
Possible cause
No mains voltage.
Loose contacts.
Main switch defective.
Blown fuse.
Faulty transformer.
Faulty PCB. Motor got stuck.
Motor defective.
Extraction fan polluted.
Filters clogged or saturated (*).
False air is being sucked (*).
Ioniser and/or collector are saturated or mounted
incorrectly (*) causing short-circuiting.
No power on filtercell(s).
Poor contacts in the ioniser and/or collector.
High-voltage transformer defective.
High-voltage PC board defective.
Short-circuit in the ioniser and/or collector
(caused by bent lamellas).
Ioniser and/or collector incorrectly mounted.
Ioniser and/or collector heavily polluted.
Ioniser and/or collector not totally dry.
Bent collector lamellas.
Bent or broken ionisation wires.
Metal particles in ioniser and/or collector.
Solution
Clean the filters. See chapter 9.
Check or replace the sealing material.
Clean the filters and mount correctly.
See chapter 9.
Press the "reset" button.
Check and repair.
Replace the high-voltage transformer.
Replace the high-voltage PC board.
Check and repair. See chapter 9.
Mount correctly.
Clean the filters. See chapter 9.
Allow thorough drying after cleaning. See chapter 9.
Repair. See chapter 9.
Replace. See chapter 9.
Clean the filters. See chapter 9.
Solution
Check the mains voltage.
Repair the contacts.
Repair or replace the main switch.
Replace the fuse.
Repair of replace the transformer.
Replace PCB.
Repair or replace motor.
Celan the extraction fan.
Clean the filters. See chapter 9.
Check or replace the sealing material.
Clean the filters and mount correctly.
See chapter 9.
Press the "reset" button.
Check and repair.
Replace the high-voltage transformer.
Replace the high-voltage PC board.
Check and repair. See chapter 9.
Mount correctly.
Clean the filters. See chapter 9.
Allow thorough drying after cleaning. See chapter 9.
Repair. See chapter 9.
Replace. See chapter 9.
Clean the filters. See chapter 9.
- article number of the particular part
- description
- quantity