Interruption of operation

Smoke spillage around door:
could be due to too low draught in the chimney <12Pa
• check whether the flue or chimney is blocked
• check whether the extraction hood is switched on; if it is, switch it off and open a
window/door in the proximity of the stove for a short while.
Soot on glass:
could be caused by the firewood is too wet.
• make sure that the stove is heated properly when firing up, prior to closing the
door
Stove is burning too strong:
could be caused by:
• leak around the door seal
• chimney draught too large >22 Pa, draught control regulator should be installed.
Stove is burning too weakly:
could be caused by:
• too small amount firewood
• too little air supply for room ventilation
• unclean smoke channels
• leaky chimney
• leakage between chimney and flue
If your stove continues to malfunction, we recommend that you contact your RAIS
distributor or chimney sweep.
WARNING!!
In case of chimney fire:
• shut off all air supply from outside (if installed) to the stove
• contact the fire department
• never attempt to put out fire with water!
• afterwards, you should ask your chimney sweeper to check the stove and chimney
IMPORTANT!!
• to ensure safe burning there must be clear yellow flames or clear embers at all
times.
• the firewood should not be smouldering.