10. Example applications for sliding door and gates
(Example 1). Connect opening and closing limit
switches N.C. contacts to plug 12-0-11;
or
(Example 2). Connect opening and closing limit
switches N.C. contacts to terminals 0-11-12.
With the above connections, when limit switches
operate the wing stops.
In the event of obstacle detection, the wing stops
and releases during opening operation and reo-
pens during closing operation.
NOTE: if the self-controlled safety edge
i
SOFA1-SOFA2 is used, make the con-
nections indicated in par. 4.1.
When control panel is used for sliding automations ope-
rations:
- set JR6=OFF;
- set TM=MAX;
- select the proper opening direction by means of DIP2.
37
DIP2=OFF
ON
ON
1
2 3 4
1
2 3 4
12 0 11
DIP2=ON
ON
1
2 3 4
DIP2=OFF
ON
ON
1
2 3 4
1
2 3 4
12 0 11
DIP2=ON
ON
1
2 3 4
<MAX
MAX
R1
TC TM
JR6
12
11 0 1 5 6 8 9 41
<MAX
MAX
R1
TC TM
JR6
12
11 0 1 5 6 8 9 41