Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43

4. Commands

WARNING: Make a jumper on all N.C. contacts if not in use. The terminals with the same
number are equal.
Command
1
5 N.O. STEP-BY-STEP
6 N.O. CLOSING
1
41
6 N.C. SAFETY STOP
41
8 N.C. REVERSAL SAFETY
1
9 N.C. STOP
9 N.O. HOLD-TO-RUN
1
0
11 N.C. CLOSING
0
11 N.O. CLOSING
12 N.C. OPENING
0
0
12 N.O. OPENING
Function
Description
With DIP1=OFF and TC<MAX, the closure of the contact activates
WITH
an opening or closing operation in the following sequence: open-
AUTOMATIC
stop-close-open. NOTE: the stop is not permanent, but has the
CLOSING
duration set by TC.
STEP-BY-STEP
With DIP1=OFF and TC=MAX, the closure of the contact activa-
WITHOUT
tes an opening or closing operation in the following sequence:
AUTOMATIC
open-stop-close-open.
CLOSING
OPENING WITH
With DIP1=ON and TC<MAX, the closure of the contact activates
AUTOMATIC
an opening operation.
CLOSING
OPENING
With DIP1=ON and TC=MAX, the closure of the contact activates
WITHOUT
an opening operation.
AUTOMATIC
If 6→4=ON, with the automation idle, contact 1-5 performs the
CLOSING
closure operation as well.
If 6→4=OFF, the closure operation is performed by contact 1-6.
With 6→4=OFF, the closure of the contact activates a closing operation.
The opening of the safety contact stops and prevents any movement.
Opening the safety contact triggers a reversal of the movement
DEVICE
(reopening) during a closing operation.
Opening the safety contact stops the current operation.
EMERGENCY STOP To enable the emergency stop function (e.g. with a specific red
button), connect the opening and closing controls to terminal 9
instead of 1 (9-5, 9-6).
Permanently opening the safety contact enables the operator
FUNCTION
presence dependent function. In this state, the opening (1-5) and
closing (1-6) controls function only if held in the pressed position,
and the automation stops when the controls are released. Any
safety devices, plus the automatic closing, are disactivated.
With DIP2=OFF, the opening of the contact blocks the movement
LIMIT SWITCH
of the automation during the closing phase.
With DIP2=ON, the opening of the contact blocks the movement
of the automation during the opening phase.
Alternatively, you can connect the limit switch to the fastons 0-11
(in this case, the terminals 0-11 must not be jumped).
In the event of obstacle detection during closing and before the
PROXIMITY
activation of the proximity limit switch, the door wing reopens;
SWITCH
after the activation of the proximity limit switch, the door wing
blocks against the mechanical closing stop.
With DIP2=OFF, the opening of the contact blocks the movement
LIMIT SWITCH
of the automation during the opening phase.
With DIP2=ON, the opening of the contact blocks the movement
of the automation during the closing phase. Alternatively, you
can connect the limit switch to the fastons 0-12 (in this case,
the terminals 0-12 must not be jumped).
In the event of obstacle detection before the activation of the
PROXIMITY
proximity limit switch while opening, the door wing stops,
SWITCH
performing a disengagement operation; after the activation
of the proximity limit switch, the door wing blocks against the
mechanical opening stop.
28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ditec e1aj

Table des Matières