Tools for installation

1 Level meter
4 Drill head
7 Open-end wrench
10 Vacuum pump
13 Inner hexagon spanner
Note:
● Please contact the local agent for installation.

Selection of installation location

Basic requirement
Installing the unit in the following places maycause malfunction. If it is un-
avoidable, please consult the localdealer:
1.The place with strong heat sources, vapors, flammableor explosive gas, or
volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical
equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall not be installed in the laundry.
8. It's not allowed to be installed on the unstable or motive base structure
(such as truck) or in the corrosive environment (such as chemical factory).
Outdoor unit
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
2 Screw driver
5 Pipe expander
8 Pipe cutter
11 Pressure meter
12
3 Impact drill
6 Torque wrench
9 Leakage detector
12 Universal meter
14 Measuring tape