Gree GWH09ACC-K6DNA1A/I Manuel D'utilisateur page 38

Climatiseur split. inverter
Masquer les pouces Voir aussi pour GWH09ACC-K6DNA1A/I:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
3. Remove the wire clip; connect the power connection wire to the wiring terminal
according to the color; tighten the screw and then fix the power connection wire
with wire clip.
Note: the wiring board is for reference only, please refer to the actual one.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
cable-cross
hole
power connection
wire
N(1)
2
2
3
blue
brown
black
Outdoor unit connection
34
yellow-
green

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières