7. Route low voltage wiring (black and yellow wires) to
the LuminIce™. Install wire clip and route wires
close to evaporator bulkhead to assure harness is
away from any moving parts, then snap wire
harness connectors together.
8. Install LuminIce™ hoses.
Insert hose closest to the front of the ice machine in
the bottom evaporator bulkhead hole.
Insert hose farthest from the front of the ice machine
in the upper evaporator bulkhead hole.
Install wire clip and route wires
along evaporator bulkhead.
9. Install the notched evaporator dust cover from kit
and test run the ice machine and LuminIce™. The
Luminice™ is energized whenever power is applied
to the ice machine.
Part Number 000008463 10/11
LuminIce™ Installation 48" Wide Single
Evaporator Models
!
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. To allow access for LuminIce™ tubing, the
evaporator dust cover and plastic caps in the
evaporator and compressor compartment bulkhead
wall must be removed and discarded. Remove the
evaporator dust cover to access lower cap.
Remove Dust Cover
Remove Plastic Caps From Bulkhead In The
Evaporator And Compressor Compartment
Installation Instructions