NOTE: Flake ice machines use an auger to remove ice from the evaporator. Occasional noises (creaks, groans,
squeaks, or pops) are a normal part of the ice making process.
Evaporator Low Temperature Safety
Thermostat and Bin Thermostat
The bin thermostat sensing bulb is located in the ice
chute or bin and turns the ice machine on and off as the
level of ice in the ice chute or bin changes.
Model
RF0244
RFS0244
RNS0244
RF0266
RF0300
RFS0300
RNS0300
RF0385
RNS0385
RF0388
RF0399
RF0644
RNS0600
RF0650
RFS0650
RNS1000
RF1200
RFS1200
RF2300
RFS2300
4
3
5
SMALL NUMBERS = LESS ICE IN BIN
LARGE NUMBERS = MORE ICE IN BIN
6
2
7
1
4
3
5
EVAPORATOR LOW TEMPERATURE
6
2
INCORRECT SETTINGS WILL CAUSE ICE
7
1
Part Number 000007644 8/14
Bin
Evaporator
Thermostat
Thermostat
Setting
Setting
5
5
5
6
5
5
5
5
4
7
3
---
3
6
5
7
5
7
5
7
5
7
5
---
3
---
3
---
3
---
3
---
4
---
3
---
3
---
3
---
BIN THERMOSTAT
SAFETY THERMOSTAT
MACHINE TO SHUT OFF
Section 3

Operation

RF0244/RF0266/RF0385/
RF0388/RF0399/RF0644 & RNS0244/
RNS0385 Operation
The ice machine will not start until:
A. The rocker switch is moved to "ON".
B. Ice does not contact the bin thermostat bulb.
C. The water reservoir is full of water.
Placing the toggle switch in the ON position starts the
gear motor and refrigeration system. The float valve
controls the water inlet valve and water level. The freeze
cycle ends when ice contacts the bin thermostat. The ice
machine will restart when ice no longer contacts the bin
thermostat.
SENSING BULB IS
LOCATED IN BIN
BIN THERMOSTAT
LOCATION
EVAPORATOR LOW
TEMPERATURE SAFETY
THERMOSTAT LOCATION
21