Castolin Eutectic TotalArc2 3000 Mode D'emploi page 42

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Warning! The coolant circulation must be checked at
regular intervals while the machine is in operation - it
must be possible to see that the return-flow to the
reservoir is working correctly.
Setting the shielding-gas rate
- Plug in the mains plug
- Shift the mains switch
- Press the "Gas test" button
- Turn the adjusting-screw on the underside of the pressure
regulator until the manometer indicates the desired flow-
rate
Mounting the wire spool
- Shift the mains switch
- Open the wire-spool cover (DS III) or the left side panel of the
TotalArc² 3000 power source
- Take off the side panel from the power source
- Mount the wire spool onto the spool holder
round
- Latch the locking bolt into the opening provided on the body
of the spool
- Adjust the braking force with the clamping screw
- Replace the wire-spool cover or side panel
N.B.! The brake should always be adjusted so that the wire
does not continue unreeling after the end of welding - but
without overtightening the clamping screw, as this would cause
motor overload.
Warning! Make sure that the wire-spool is sitting firmly
on the spool holder.
Feeding in the wire electrode
- Shift the mains switch
- Open the wire-spool cover (DS III) or the left side panel of the
TotalArc² 3000 power source
- Remove the left side panel of the power source
- Pivot the clamping devices
- Pull the pressure levers
- Insert the wire electrode though the infeed tube
roller drive and around 5 cm into the infeed tube of the
welding torch
- Push the pressure levers
- Pivot the clamping devices
- Set the contact pressure by means of the clamping nuts
and
N.B.! Set a contact pressure that is high enough to ensure
smooth wire feed, but not so high that the wire electrode is
deformed.
- Arrange the hosepack in as straight a line as possible
- Detach the gas nozzle from the torch
- Unscrew the contact tube
- Plug in the mains plug
- Shift the mains switch
Warning! During the wire-infeed operation, hold the
welding torch facing away from your body.
into the "I" position
into the "O" position
- the right way
into the "O" position
and
forwards
and
upwards
of the 4-
and
downwards
and
into the vertical position
into the "I" position
- Press the wire-inching button
protrudes out of the end of the torch
- To end the wire-infeed operation, release the wire-inching
button
N.B.! The wire spool must not continue to unreel after you
release the torch trigger. Re-adjust the brake if necessary.
- Screw in the contact tube
- Fit the gas nozzle
- Close the wire-spool cover or side panel
- Shift the mains switch
Fig.8
4-roller drive
Changing the feed rollers
In order to achieve satisfactory wire travel, the feed rollers must
be suitable for the diameter and alloy of the wire to be welded.
- Shift the mains switch
- Open the wire-spool cover (DS III) or the left side panel of the
TotalArc² 3000 power source
- Remove the left side panel of the power source
- Pivot the clamping devices
- Pull the pressure levers
- Pull out axles
-
- Remove feed rollers
- Insert new feed rollers
N.B.! Insert the feed rollers in such a way that you can still see
and read the designation for the wire diameter.
- Push axles
-
back in again - the anti-twist lock of each
axle must latch into place
- Push the pressure levers
- Pivot the clamping devices
- Set the contact pressure by means of the clamping nuts
and
- Close the wire-spool cover or side panel
42
until the wire electrode
into the "O" position
into the "O" position
and
forwards
and
upwards
-
and
downwards
and
into the vertical position

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Totalarc2 4000Totalarc2 5000

Table des Matières