The Kinetico Drinking Water System Plus Deluxe
Cartridge Changes and Sanitization
If you choose to change the cartridges on your Kinetico Drinking Water
System Plus Deluxe yourself, you must use a sanitization kit available from
your Kinetico dealer. Follow these instructions to fully sanitize your system.
Wash your hands thoroughly and do not touch any internal portions of the
system. Or call your local, authorized Kinetico dealer who can change the
necessary filters, disinfect your system and analyze your water to be sure it is
of the best quality.
NOTE: Although great care is taken to provide a sanitized drinking water unit, possi-
ble contamination can result from vendor products, assembly, packaging, shipping or
extended storage time. Proper sanitization is required.
WARNING: To avoid possible injury and property damage, this system must
be properly depressurized before attempting to remove any cartridge or other
component.
NOTE: Be prepared to catch any water when disconnecting and sanitizing your system.
1) Remove the decorative cover (Fig. 1). Close the cold water supply valve and
the storage tank shutoff valve. Open the tap (Fig. 2) to help depressurize the
system. Wait until all the flow stops at the open tap before continuing (this
may take several minutes). Remove the exhausted MACguard Filter car-
tridge and the prefilter cartridge (Fig. 3) and discard them. Be prepared to
catch accidental water spills when removing the cartridges.
NOTE: If your system was installed with an air-charged storage tank (not a QuickFlo
tank), please proceed to step 14, page 15.
Sanitization Procedure When Using QuickFlo Storage Tank
2) Fill the sanitizer cartridges 3/4 full with clean water. Add 1 dropper (5 ml)
of regular, unscented household bleach (6% sodium hypochlorite) to the
center of each cartridge (Fig. 4). Install the sanitizer cartridges to the prefilter
and postfilter heads.
3) Remove the module securing clip from the bracket manifold by squeezing
the sides inward and pulling the clip off (Fig. 5). Remove the RO module
from the center of the bracket manifold (Fig. 6). Install the sanitizer assem-
bly to the center of the bracket manifold (Fig. 7). Fasten the module clip to
the bracket manifold to secure the sanitizer assembly (Fig. 8).The clip must
snap into place on both sides (Fig.9).