4) Be sure the storage tank shutoff valve and the drinking water tap are open.
Disconnect the drain line from port # 3 on the RO manifold and secure the
end of the tubing in a bucket or pan.
5) Slowly open the cold water supply valve until there is a constant flow from
the open drinking water tap. (Be prepared for some air to be discharged from
the open tap.) Close the cold water supply valve. When all the flow stops
from the drinking water tap, close the drinking water tap.
6) Remove the prefilter sanitizer cartridge.Again add 5 ml of unscented house-
hold bleach (6% sodium hypochlorite) to the center of the cartridge.
Reinstall the prefilter sanitizer cartridge.
1