Response

Characteristic
Measuring rate
Response time t 99 *
* Time after change of input value until reaching an output value of 99 % steady
state

Power Supply

P 32300 P0/x0

Isolation

Test voltage
Working voltage
(basic insulation)
Rising / falling linearly; via IrDA:
curve defined by sampling points or
polynomials
Approx. 3/s
Approx. 2/s in operating mode
resistance measurement
5 k ... 100 kΩ
300 ms
500 ms in operating mode
resistance measurement
5 k ... 100 kΩ
24 V DC, - 20 %, + 25 %, 0.85 W
2.5 kV, 50 Hz: power supply against
input against output
Up to 300 V AC/DC across all circuits
with overvoltage category II and
pollution degree 2. For applications
with high working voltages, take
measures to prevent accidental
contact and make sure that there
is suffi cient distance or insulation
between adjacent devices.
Specifi cations