10 | English
(d) Battery state of charge
(e) Compass View with reference point
Technical Data
Digital inspection camera
Article number
Rated voltage
Non-rechargeable batteries
(alkaline manganese)
Relative air humidity
Length of camera cable
Smallest bend radius of camera
cable
Camera head diameter
Display resolution
Approx. operating time
Weight according to
EPTA‑Procedure 01:2014
Dimensions
(length × width × height)
Operating temperature
Storage temperature (handheld
device without batteries)
A) Free of condensation
B) at 50 % brightness of the light in the camera head
Assembly
Inserting/changing the batteries
Using alkali-manganese batteries is recommended to oper-
ate the inspection camera.
To open the battery compartment cover (12), press the
locking mechanism (13) and lift open the battery compart-
ment cover (12). Pull out the battery compartment (11) and
insert the batteries. When inserting the batteries, ensure
that the polarity is correct according to the illustration on the
inside of the battery compartment (11). Push in the battery
compartment (11) as far as it will go and close the battery
compartment cover (12).
If the state of charge of the batteries is low, the
will first appear in the display. When the battery symbol is
empty, you have to replace the batteries because inspec-
tions are no longer possible.
Always replace all the batteries at the same time. Only use
batteries from the same manufacturer and which have the
same capacity.
Remove the batteries from the inspection camera
u
when not using it for longer periods. The batteries can
corrode and self-discharge during prolonged storage.
1 609 92A 63C | (04.11.2020)
Fitting the camera cable (see figure A)
For operation of the inspection camera, the camera
cable (7) must be fitted on the handheld device (1).
Push the connector of the camera cable (7) onto the camera
connection (14) in the correct position until it clicks into
GIC 120
place.
3 601 B41 1..
Removing the camera cable (see figure B)
V=
6
4 × 1.5 V LR6
To remove the camera cable (7), press the locking
(AA)
mechanism (15) and pull the connector out of the handheld
device (1).
A)
%
5–95
m
1.2
Fitting the mirror, magnet or hook (see figure C)
mm
25
The mirror (18), the magnet (16) and the hook (17) can be
fitted on the camera head (8) as accessories.
mm
8.5
Push one of the three accessories, as shown in the figure, all
320 × 240
the way onto the recess on the camera head (8).
B)
h
5
Note: The magnet (16) and the hook (17) are only suitable
for moving and removing loose, small and light objects. The
kg
0.5
inspection camera or the accessory can be damaged with
too strong a pull.
mm 197 × 85 × 49
Operation
°C
–10 to +50
Keep the handheld device (1) and the batteries dry
u
°C
–20 to +60
and protect them from direct sunlight. The camera
cable and camera head are watertight if assembled cor-
rectly. However, the handheld device and the batteries
are not protected against water. If they come into contact
with water, there is a risk of electric shock or damage.
Do not use the inspection camera if the lens on the
u
camera head (8) has fogged up. Switch the inspection
camera on only if the moisture has evaporated. The in-
spection camera may otherwise become damaged.
The switched-on light (9) can become hot during oper-
u
ation. To avoid burns, do not touch the light.
Do not subject the inspection camera to extreme tem-
u
peratures or variations in temperature. For example,
do not leave it in a car for extended periods of time. In
case of large variations in temperature, allow the inspec-
tion camera to adjust to the ambient temperature before
putting it into operation.
Starting Operation
symbol
Switching On and Off
To switch on the inspection camera, press the On/Off
button (2). The start screen is shown in the display (5) for a
short time.
Note: If the camera cable is not fitted when switching on, the
display will show an error message.
To switch off the inspection camera, press the On/Off
button (2) again.
If no button on the inspection camera is pressed for approx.
20 minutes, then the inspection camera will automatically
switch itself off to preserve battery life.