Tallas Pumps D-BOOSTI P1-1100 Instructions Pour L'installation Et La Maintenance page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
Function
Auto Mode
Manual mode
Anti-leakage
Cut in
Cut out
Max pump on
(B) MODE selection button
Selectable modes:
1) AUTO_MODE;
2) MANUAL_MODE;
3) ANTI LEAKAGE;
4) CUT_IN;
5) CUT_OUT,
6) MAX_PUMP_ON;
To unlock the choice of function press "MODE" button for 5 seconds.
Press "MODE" to scroll through the various operating modes (AUTO_MODE or MANUAL_MODE) or parameters to be
modified (CUT IN and CUT OUT) or to enable certain functions (ANTI-LEAKAGE and MAX PUMP ON). While scrolling
through the modes, the LED of the function selected will flash. On returning to AUTO_MODE the active functions will be
highlighted by the relative LED lighting up with a steady light. See paragraph 2 (Description of the functions).
Indicators on "MODE"
AUTO MODE: the pump will work in automatic mode see 9.2.1
MANUAL MODE: the pump works in manual mode see 9.2.1, and the user can decide when to switch it on or off by acting
on the "SET" button. SET-ON switched On SET-OFF switched Off.
CUT-IN: pressure setting (always enabled) minimum pressure below which the pump is activated, can be set between 1.5
and 3.0 bar, factory setting 1.8 bar; the pump is activated even if the flow is less than a minimum value of 1.5 l/min, factory-
setting.
CUT-OUT: pressure setting (enabled) above which the pump stops, the factory setting for "CUT-IN" + 1 bar (1 Led
enlighted), but can be increased up to 3.5 bar (50.8 psi).
To enable it select the function by pressing "MODE" until the LED corresponding to CUT-OUT flashes then:
Display configuration
ENGLISH
Set
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
Increase/Decrease
Increase/Decrease
OFF: disabled
ON: enabled
OFF: disabled
5
Alarm Reset
Press SET