5. From a street panel, make a call to the fi rst address in the range. The last address should
be greater than the fi rst one. All leds should be off.
Notice:
- To confi gure the fi rst and last addresses in the range to make the call from a push-button
panel, press the corresponding buttons for these addresses as indicated in steps 4 and
5. Remember that if the panel has a keypad, the call is made by entering the residence
number + the bell key.
Steps to DELETE the entered range.
1.
Press the PRG button twice, the D led should light up.
2.
Simultaneously press the Sec/Single and Min/All buttons. All leds should be off. The range
entered has been deleted.
Third step: Confi guration of the activation time.
To confi gure the activation time, follow point: 2.2 ACTIVATION TIME CONFIGURATION VIA
THE INTEGRATED BUTTONS (SEC/SINGLE - MIN/ALL)
2.5.2.3 ACTIVATING OR DEACTIVATING THE RELAY UPON RECEIVING AN ACTIVATE
F1 RELAY COMMAND
Function description.
You can confi gure the relay to activate or deactivate upon receiving the activate or deactivate
the F1 relay:
a) Transmitted by a phone or
b) Transmitted by a duox relay confi gured as explained in section:
section 2.5.1.4 ACTIVATION OR DEACTIVATION FUNCTION OF F1 RELAY. See cod.
97822 Advanced Manual Duox Relay in www.fermax.es
Relay confi gured
(the one being con-
fi gured as SEND of
the Activation or De-
activation command
on the F1 relay)
MIN ALL
SEC SINGLE
PRG
TX
MADE IN SPAIN
MODULO RELE
transmitter relay
a) F1 transmitted by a phone
The residence terminals must have an F1 button to send the F1 command, (for example, the
loft duox extra phone).
Upon pressing the F1 button on the phone, it sends the F1 command. The relay, if confi gured
this way, can be activated upon receiving the command.
Page 16
as SEND F1
B
B
C
D
BUS
T
OUTPUT
PRG
RX
TX
RELAY
RESET/
ON
DISABLE
SET
C
-
NC
V
OUT
+12V
NO
REF.
3257
BUS INPUT
DUOX RELAY
DUOX
MODULE
FERMAX ELECTRONICA, SAU
12V 0.3A
OUTPUT
AV TRES CRUCES, 133
46017 VALENCIA - SPAIN
B
B
ORIGIN
2.5.1. TX Operating mode
Relay confi gured as
activation/deactivation
upon RECEIVING F1
B
B
C
MIN ALL
D
BUS
T
OUTPUT
SEC SINGLE
RX
TX
PRG
RELAY
RESET/
DISABLE
SET
-
V
OUT
+12V
REF.
RX
3257
MADE IN SPAIN
BUS INPUT
DUOX RELAY
MODULO RELE
DUOX
MODULE
FERMAX ELECTRONICA, SAU
12V 0.3A
OUTPUT
AV TRES CRUCES, 133
46017 VALENCIA - SPAIN
B
B
DESTINATION
receptor relay
(confi gured as Activ-
ation or Deactivation
upon RECEIVING
an Activate F1 relay
command.
PRG
ON
C
NC
NO

Publicité

Table des Matières
loading

Table des Matières