Connecting the unit to the flow-through filter.
Vitronic 18 W, 24 W, 36 W
The unit is suitable for connection to flow-through filters. Both outlet sockets are screwed to
the inlet nozzles on the flow-through filter. Adhere to the instructions for use of the flow-
through filter.
How to proceed:
1. Unscrew the closing cap.
2. Guide the two outlet sockets with the flat seal through the two holes in the container wall of
the flow-through filter.
3. Screw the inlet nozzle with the O-ring onto the outlet socket and hand-tighten the inlet noz-
zle.
4. Connect the supply hose to the inlet socket. (→ Establishing the connections)
Commissioning/start-up
Start-up sequence:
1. Switch on the pump and wait until the casing of the UVC clarifier is filled with water.
2. Switch on the UVC clarifier.
– Never run the UVC clarifier without water flowing through.
3. Check the UVC clarifier function.
4. Check all connections for leaks.