1. 10.05.2016 — local date in DD.MM.YYYY format.
2. 05:43:23 — local time in hh:mm:ss format.
3. OK — status code. Can be one of the following:
OK — no error
NA — Device could not get NMEA 2000 address. This can happen if there are more than 252
NMEA devices in the NMEA 2000 network.
IS — Invalid state. The Device is connected improperly. This status indicates that the gauge
reference voltage is applied to the corresponding Device input, but the «CONNECTION»
setting is set wrong. Refer to Section VI.4.
ID — Invalid data. Fluid level sensor resistance measurement is greater than 400 Ohm.
Usually indicates sensor or wiring fault or incompatible sensor type.
4. #01 — Tank number (NMEA 2000 Fluid Level Instance). Refer to Section VI.2.
5. Level 37.7%, — Measured tank level in percent (with calibration applied). Note the leading space(s)
and separator coma.
6. 754.1 L — Measured tank level in liters.
If the tank volume is not configured («CAPACITY» setting is set to «UNKNOWN») the value
will be set to «----- L»
If the measured level is > 1000, the fractional part will be ignored, e. g. «1023 L».
In the pressure sensor mode (see VI.17), the last parameter in the log file is replaced by the pressure value
in Pascals.