YD:VOLTS_EMPTY <number> YD:VOLTS_EMPTY 0.0
YD:VOLTS_FULL <number>
YD:CONNECTION <type>
YD:COIL_1 <number>
YD:COIL_2 <number>
YD:WIRES <number>
YD:PRESSURE <number>
YD:VOLTS_FULL 5.0
YD:CONNECTION RESISTIVE
YD:CONNECTION MDI
YD:CONNECTION 1COIL
YD:CONNECTION 2COIL
YD:CONNECTION 2COIL_VCC
YD:CONNECTION VOLTAGE
YD:COIL_1 330.65
YD:COIL_2 240.5
YD:WIRES 0.48
YD:PRESSURE 10000
— 32 —
Voltage-output
fluid
voltage for an empty tank. Range:
from 0 to 16. See Section 1.4. (Note 1)
Voltage-output
fluid
voltage for a full tank. Range: from 0
to 16. See Section 1.4. (Note 1)
Tank level sensor connection method.
RESISTIVE: standalone connection,
1COIL: in parallel with 1-coil gauge,
2COIL and 2COIL_VCC (see Section
III): in parallel with 2-coil gauge,
MDI: in parallel with Volvo MDI box,
VOLTAGE: for fluid level sensor with
voltage output. (Note 1)
Coil 1 resistance in Ohms for 2COIL
connection or single coil resistance
in Ohms for 1COIL connection.
Range: from 0.00 to 10000.00.
(Note 1)
Coil 2 resistance in Ohms for 2COIL
connection.
Range:
to 10000.00. (Note 1)
Sensor
wires
parasitic
in Ohms
Range: from 0.00 to 100.00. (Note 1)
Converts the Tank Adapter to pressure
sensor (see VI.17). Range: -30000
to 30000, 0 – OFF. (Note 1)
Table 1 continued