Manufacturer
Lubricant
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level and top up if necessary.
Using the oil dipstick pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing: the
oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in Fig. 14 chapter 11.
The quantity required is ~ 2 litres.
Viscosity / Room Temperature diagram
mm
2
/s = cSt
The used oil must be placed in a suitable container and disposed of in special centres.
It absolutely should not be discarded into the environment.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0°C - 30°C, follow
the instructions in the following diagram, considering that oil
must have a minimum viscosity of 180 cSt.
Ambient temp. (°C)
23
Fig. 3