Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Caution!
Ensure correct polarity.
Each core cable colour must be in the same cable core guide on both union nuts.
When the union nut is being tightened, an electric contact and the pull-relief are
automatically established.
Special seals provide protection against dust and water.
The coin-activated switch is only suitable for on-wall installation.
Important!
Align the coin-activated switch horizontally.
Failure to observe can cause the coin tester to malfunction.
11.6 Unscrew the frame of the coin-activated switch (PIN-Torx TX-15).
11.7 Screw on the electronic T-junction.
11.8 Mount the frame on the wall horizontally.
11.9 Guide the system line through the frame into the coin-activated switch.
11.10 Clip the coin-activated switch on to the top of the tongue and attach.
11.11 Use the screws to fix the coin-activated switch at the bottom.
11.12 Install the line connection between the coin-activated switch and the electronic T-
junction.
11.13 Insert the coin receptacle.
11.14 Close the door of the coin-activated switch.
11.15 The coin-activated switch is ready for operation.

12. Commissioning

Each shower must be assigned a shower unit number to ensure correct operation.
12.1 Switch on the power supply.
12.2 Wait at least 4 minutes. The switching of the set and operating modes now
functions.
All Aquapay fittings must be in the "Set B" operating mode.
All Aquapay fittings must be set to AQUAPAY master operation with the system
software (see instructions 18-05.648, Special Functions Chapter).
12.3 All Aquapay fittings are switched to the "Set B" operating mode in the system
software or at the ECC function controller.
12.4 Switch off the power supply.
12.5 Put the jumper (b) over the two upper pins on the Aquapay module (a).
12.6 Switch on the power supply.
- 7 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

7612982130809

Table des Matières