Dometic TEC 30D EV Notice D'utilisation page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
TEC30D EV
Display message
Description
GEN CAL
Message appears when the
generator is started up; it
shows the calibration phase
which takes place before
each start-up. The generator
does not supply any voltage.
GEN WAIT
Message appears while you
are waiting for the generator
to start again.
GEN ON
The generator is operating
normally.
GEN OFF
8.7
Checking the oil level
!
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
I
NOTE
The generator must be level.
Always check the oil level before use. To do this, proceed as follows (fig. 4,
page 5):
➤ Open the generator cover (2).
➤ Switch the generator to no function with the main switch (1).
➤ Take the dipstick (3) out of the filler neck (4).
➤ Clean the dipstick (3) with a cloth.
➤ Put the dipstick (3) back into the filler neck (4).
➤ Take the dipstick (3) out of the filler neck.
EN
Generator behaviour
The generator is running but
does not supply any voltage.
The generator is switched
off.
Normal mode
The generator is in stand-by
and can be started.
Operating the generator
Measures
Wait a moment.
Wait until the message has
disappeared then attempt
ignition again.
21

Publicité

Table des Matières
loading

Table des Matières