To get the best from your SmartPower Energizer
The SmartPower Energizer is a commitment to a reliable, high performance Power Fence system. To gain optimum
performance from your energizer you may need to improve your earth system, the quality of your lead-outs, fence
design and construction. Please read the "Understanding your SmartPower Energizer" sections of this manual
to understand what the LCD information tells you. This information will help you achieve a very reliable, high
performance Power Fence system.
Use Gallagher Power Fence™ accessories to gain maximum performance from your SmartPower Energizer.
Accessories
Your SmartPower Energizer is supplied with the following:
SmartPower XR1 Remote Control with pouch (except for special promotional offers where it may be purchased
separately)
3 mounting screws
SmartPower operator's manual
Quick reference help guide
Gallagher Power Fence™ Manual
Note: Battery lead not included.

INSTALLATION GUIDE

Mains Operation only
See "For Mains Operation with Battery Back-up and for Battery Only Operation", for installing
the energizer with battery back-up or with full battery operation.
Step 1: Install the Energizer
a)
Mount the energizer on a wall, under cover, out of reach of children. Install where there
is no risk of the energizer incurring fire or mechanical damage and if possible away
from heavy electrical equipment eg. pumps or other items that may cause electrical
interference.
Note: Install the energizer in a frequently accessed place. The displays and alarms give
valuable information that can save time and help prevent costly problems.
b)
Using the template on centre pages, drill 3 x 4mm (
provided into the wall leaving the head of the screw about 3mm (
Place the energizer over and slide down onto the mounting screws.
Step 2: Connect to earth (ground) system
Using Underground Cable (G6270) remove 5cm (2") of plastic coating from one end of the cable and connect to the
green ( ) terminal on the energizer. Attach the cable to the earth system by removing 10cm (4") of insulation from
the cable at each Earth Stake (G8790), then clamp the
exposed wire to each stake using an Earth Clamp (G8760). Tighten the clamp.
For further instructions on the earth (ground) system see the Gallagher Power Fence™
Manual enclosed.
Reference Earth:
An additional earth stake is required to allow correct measurement of the earth
voltage. Install a single stake (G8780) at least 60cm (2ft) long, at least 5m (16ft)
from the main energizer earth system and at least 10m (33ft) from any power
supply earth peg, underground telephone or power cable. Using Underground
Cable (G6270) connect the reference earth stake to the black ( ) terminal on
the energizer.
If the Reference Earth is not connected, the earth voltage display will flash 0.0.
IMPORTANT:
Note that if your earth is near perfect, the display may also flash 0.0. To confirm that your earth system is
good check the voltage at the stakes is 0.0.
TM
/
5
32
") holes (A,B & C). Fix the screws
/
") out from the wall.
1
8
RED
To Fence
To Earth System
Installation Guide
BLUE
To Section of Fence
GREEN
BLACK
To Reference Earth
7

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Smartpower mbx2500

Table des Matières