Gallagher M1800i Notice D'utilisation page 15

Masquer les pouces Voir aussi pour M1800i:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Gallagher 3E2489 M1800i M2800i Energizer User Manual
Adjusti ng / Turning Off Alarms
a)
Press the setup butt on (
b)
Press the navigati on butt ons (< or >) to move the zone indicati on arrow (
over the desired zone, which will fl ash when selected.
c)
Press (- or +) to adjust the zone alarm level. The higher the alarm level is set,
the more sensiti ve the zone will be to faults.
d)
To disable an alarm press (-) unti l the display shows (- -).
e)
To exit, press the setup butt on (
Earth System Voltage and Alarm
View the earth system performance by pressing the navigati on butt ons (< or >) while
the energizer is operati ng unti l the zone indicati on arrow (
earth zone (
installed. If there is no reference earth it will display 0.0KV. If the earth voltage rises
above the earth alarm level (default 0.5KV) the status LED will fl ash red, the earth
zone indicator will be highlighted and the internal buzzer will sound on the energizer.
The buzzer can be muted by pressing any key on the controller.
See Adjusti ng / Turning Off Alarms secti on above to adjust or turn off the earth
system alarm.
).
Controller showing the energizer alarm setup at 3.0KV
). The earth voltage will be displayed if a reference earth stake is
) or wait 10 seconds.
)
) is highlighti ng the
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M2800i

Table des Matières