the 4 sleeves C and 4 screws D as indicated.
• Fixing to the wall
Drill the holes A respecting the distances indicated (Fig.2).
Fix the appliance to the wall and align it in horizontal posi-
tion to the wall units. When the appliance has been adjusted,
definitely fix the hood using the screws A (Fig.5). For the
various installations use screws and screw anchors suited to
the type of wall (e.g. reinforced concrete, plasterboard, etc.). If
the screws and screw anchors are provided with the product,
check that they are suitable for the type of wall on which the
hood is to be fixed.
• Fixing the decorative telescopic flue
Warning! Caution! If your appliance model features the
lower connector with a tab, before fixing it in place bend
the tab inwards using a pair of pliers, as illustrated in figure
5, step1.
Arrange the electrical power supply within the dimensions of
the decorative flue. If your appliance is to be installed in the
ducting version or in the version with external motor, prepare
the air exhaust opening. Adjust the width of the support
bracket of the upper flue (Fig.3). then fix it to the ceiling using
the screws A (Fig.3) in such a way that it is in line with your hood
and respecting the distance from the ceiling indicated in Fig.2.
Connect the flange C to the air exhaust hole using a connection
pipe (Fig.5 - Stage 2). Insert the upper flue into the lower flue.
Fix the lower flue to the hood using the screws B provided
(Fig.5 - Stage 2), extract the upper flue up to the bracket and
fix it with the screws B (Fig.3). to transform the hood from a
ducting version into a filtering version, ask your dealer for the
charcoal filters and follow the installation instructions.
• Filtering version
Install the hood and the two flues as described in the paragraph
for installation of the hood in ducting version. to assemble the
filtering flue refer to the instructions contained in the kit.
If the kit is not provided, order it from your dealer as accessory.
the filters must be applied to the suction unit positioned inside
the hood. they must be centred by turning them 90 degrees
until the stop catch is tripped (Fig.8).
USE AND MAINTENANCE
• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
the effective performance of the cooker hood depends on
constant maintenance; the anti-grease filter and the active
carbon filter both require special attention.
• The anti-grease filter is used to trap any grease particles
suspended in the air, therefore is subject to saturation (the
time it takes for the filter to become saturated depends on
the way in which the appliance is used).
- to prevent potential fire hazards, the anti-grease filters
should be washed a minimum of every 2 months (it is
possible to use the dishwasher for this task).
- After a few washes, the colour of the filters may change. this
does not mean they have to be replaced.
If the replacement and washing instructions are not followed,
the anti-grease filters may present a fire hazard.
• The active carbon filters are used to purify the air which
is released back into the room. the filters are not washable
or re-usable and must be replaced at least once every four
months. the active carbon filter saturation level depends on
the frequency with which the appliance is used, the type of
cooking performed and the regularity with which the anti-
grease filters are cleaned.
• Clean the cooker hood frequently, both inside and outside,
using a cloth which has been dampened with denatured
alcohol or neutral, non-abrasive liquid detergents.
• The light on the cooker hood is designed for use during
cooking and not for general room illumination. Extended use
of the light reduces the average duration of the bulb.
• Replacing halogen light bulbs (Fig.6)
to replace the halogen light bulbs B, remove the glass pane
C using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: do not touch the light bulb with bare hands.
• Commands (Fig.9) mechanical the key symbols are explained
below:
A = LIGHt
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III.
• Commands (Fig.10) luminous the key symbols are explained
below:
A = LIGHt
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUtOMAtIC StOP tIMER - 15 minutes (*).
• If your appliance does not have the INTENSIVE speed
function, press key E for two seconds and it will be activated
for 10 minutes after which it will return to the previously set
speed. When the function is active the LED flashes. to interrupt
it before the 10 minutes have expired press key E again.
• By pressing key F for two seconds (with the hood switched
off) the "clean air" function is activated. this function switches
the appliance on for ten minutes every hour at the first speed.
As soon as this function is activated the motor starts up at
the first speed for ten minutes, During this time key F and key
C must flash at the same time. After ten minutes the motor
switches off and the LED of key F remains switched on with
a fixed light until the motor starts up again at the first speed
after fifty minutes and keys F and C start to flash again for ten
minutes and so on.
By pressing any key for the exclusion of the hood light the
hood will return immediately to its normal functioning (e.g.
if key D is pressed the "clean air" function is deactivated and
the motor moves to the 2nd speed straight away. By pressing
key B the function is deactivated).
(*) the "AUTOMATIC STOP TIMER" delays stopping of the
hood, which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
• Active carbon/grease filter saturation:
- When button A flashes at a frequency of 2 seconds, the
grease filters must be cleaned.
- When button A flashes at a frequency of 0.5 seconds, the
carbon filters must be replaced.
After the clean filter has been replaced, the electronic memory
must be reset by pressing button A for approximately 5
seconds, until the light on the button stops flashing.