BFT VISTA-SL C Instructions D'utilisation Et D'installation page 36

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
inside the cage door. If the internal door is open, this door is closed before
the external door is opened. In the event of simultaneous operations, the
external door is given priority. Once the external door is closed, it activates
opening of the internal door and allows entry inside the building.
Radar B
positioned in the middle of the cage door
presence of a person inside the cage door and, during exit, allows the external
door to open once the internal door has closed. In an emergency, once the
person has entered the cage door, if the other door fails to open, it allows the
door they have just entered through to be opened again.
Radar C internal door (2)
With doors closed, it activates opening of the internal door and allows entry
inside the cage door from inside the building. If the external door is open,
this door is closed before the internal door is opened. In the event of simul-
taneous operations, the external door is given priority.
TABLE "A" PARAMETERS MENU
PARAMETER
MIN
MAX
0
60
TCA
1
99
CLEAR T.
1
90
alar
time
partial
10
70
opening
che ist
3
30
opening
1
10
accel.
1
10
bra e
op. d ist.
1
20
sloud
cl. d ist.
1
20
sloud
op. d ist.
10
70
decel
cl. d ist.
10
70
decel
4
99
op speed
4
99
cl speed
1
99
op. f orce
1
99
cls. f orce
* Refer for universal handheld programmer.
36
- VISTA-SL C (ARIA-EVO)
INSTALLATION MANUAL
In normal mode, it detects the
(PARA )
DEFAULT
PERSONAL
4
Automatic closing time [s]
30
Clearance Time [s]
30
Alarm time [s]
50
Partial opening [%]
Chemist's opening [cm]
12
(CHAR 59) *
Acceleration ramp []
5
(Fig. C2 Rif. A)
(CHAR PERC 41) *
Deceleration ramp []
5
(Fig. C2 Rif. B)
Opening approach distance [cm]
2
(Fig. C2 Rif. E)
Closing approach distance [cm]
2
(Fig. C2 Rif. F)
Opening deceleration space [cm]
50
(Fig. C2 Rif. C)
Closing deceleration space [cm]
50
(Fig. C2 Rif. D)
Running speed during opening
60
[%] (Fig. C2 Rif. G)
Running speed during closing
60
[%] (Fig. C2 Rif. H)
75
Opening force [%]
75
Closing force [%]
15.12) DIRECTION REVERSAL FIG. AK
15.13) FIG. AK: Keep a distance "X" not exceeding 100mm between the door leaf
and the rear fixed part. If X exceeds 100mm, make safe by applying a detector
complying with EN 16005 or apply a fixed protective barrier.
16) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
17) RESTORING FACTORY SETTINGS (Fig.U)
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.U ref.1)
- Open the Stop input and press the - and OK keys together (Fig.U ref.2)
- Switch on the board's power (Fig.U ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.U ref.4)
- Wait for the procedure to finish (Fig.U ref.5)
- Procedure finished (Fig.U ref.6)
DEFINITION
Once the set time is up, if photocells are triggered, the ALARM contact
is closed (Sect. ALARM OUTPUT OPERATION MODE)
Adjusts partial opening percentage compared to total opening in
"Partial open" mode.
Centimetres the door opens by in "Chemist's open" mode.
Sets door acceleration at start (1=min., 10=max.). The autoset fe-
ature sets this parameter automatically. Should this parameter be
edited, it will be followed by a complete opening/closing cycle for
setting purposes (reported by the buzzer emitting a continuous
beeping sound and the message SET appearing on the display),
during which obstacle detection is not enabled.
Sets the door's deceleration for intermediate stopping (not at travel
limit). (1=min., 10=max.). The autoset feature sets this parameter
automatically. Should this parameter be edited, it will be followed
by a complete opening/closing cycle for setting purposes (reported
by the buzzer emitting a continuous beeping sound and the messa-
ge SET appearing on the display), during which obstacle detection
is not enabled.
Sets the approach distance to reach the opening travel limit. This
distance is travelled at low speed.
Sets the approach distance to reach the closing travel limit. This di-
stance is travelled at low speed.
Sets the distance needed for the door to move from high to low
speed during an opening operation.
The autoset function automatically sets this parameter..
Any modification to this parameter will be followed by a complete
setting manoeuvre (reported by the buzzer emitting a continuous
beeping sound and the message SET appearing on the display), du-
ring which obstacle recognition is not active.
Sets the distance needed for the door to move from high to low
speed during a closing operation.
The autoset function automatically sets this parameter.
Any modification to this parameter will be followed by a complete
setting manoeuvre (reported by the buzzer emitting a continuous
beeping sound and the message SET appearing on the display), du-
ring which obstacle recognition is not active.
Sets the running speed that the door must reach during opening,
as a percentage of the maximum speed the actuator can reach. The
autoset feature sets this parameter automatically. Should this pa-
rameter be edited, it will be followed by a complete opening/clo-
sing cycle for setting purposes (reported by the buzzer emitting a
continuous beeping sound and the message SET appearing on the
display), during which obstacle detection is not enabled.
Sets the running speed that the door must reach during closing, as
a percentage of the maximum speed the actuator can reach. The
autoset feature sets this parameter automatically. Should this pa-
rameter be edited, it will be followed by a complete opening/clo-
sing cycle for setting purposes (reported by the buzzer emitting a
continuous beeping sound and the message SET appearing on the
display), during which obstacle detection is not enabled.
Sets sensitivity to obstacles during opening (1=max., 99=min.) The
autoset feature sets this parameter automatically to a value of 10%.
The user can edit this parameter based on how sensitive the door
needs to be to obstacles.
Sets sensitivity to obstacles during closing (1=max., 99=min.) The
autoset feature sets this parameter automatically to a value of 10%.
The user can edit this parameter based on how sensitive the door
needs to be to obstacles.
DESCRIPTION

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vista-sl c aria-evoVista sl c 107-125Vista sl c 208-229

Table des Matières